Integrated CLSC Data Instances

Easwaran, G., and Üster. H., “A Closed-Loop Supply Chain Network Design Problem with Integrated Forward and Reverse Channel Decisions,” IIE Transactions, Vol. 42/11, pp. 779-792, 2010.

Note: The link to the CLSC Network Design Problem data instances is given below.

           Please right click on the link and click "Save Target As" to save it on your machine.

·    CLSC Data Instances - Model-3.zip

Format:

1.      The data instances are named M3_1.txt to M3_120.txt.

2.      There are 12 different classes. There are 10 instances under each class.

3.      The Table below gives the number of products, retailers, and collection centers in each class.

Class

Products

Retailers

Collection Centers

C1

5

60

25

C2

5

60

35

C3

5

90

25

C4

5

90

35

C5

5

120

25

C6

5

120

35

C7

10

60

25

C8

10

60

35

C9

10

90

25

C10

10

90

35

C11

10

120

25

C12

10

120

35

4.      The Legend for the input file format is given below:

Symbol

Details

 P

Products

 R

Retailers

 H

Hybrid Distribution/Collection Centers

 M(p)

Hybrid Manufacturing/Remanufacturing Plants

 D'rp

Fresh demand for product p at retailer r

 Drp

Return demand for product p at retailer r

 rhLTC

Transportation cost (per unit per mi) between retailer r and hybrid center h

 hm(p)LTC_[h][p][m]

Transportation cost (per unit per mi) between hybrid center h and hybrid plant m, associated with product p

 Delta[r][p]

Retailer return fraction for product p at location r

 Fh

Fixed cost of opening hybrid center h

 Fm(p) - mpFC[p][m]

Fixed cost of opening plant m for product p

 pdPC - [p][h]

Distribution processing cost for product p at location h

 pkPC - [p][h]

Collection processing cost for product p at location h

 POemPC[p][m]

Manufacturing cost for product p at location m

 PRemanPC[p][m]

Remanufacturing cost for product p at location m

 MCap[p][m]

(not applicable)

 Alpha[p][m(p)]

Remanufacturing coefficient for plant m for product p

 Distribution_Capacity_Coefficients

Distribution capacity coefficient for product p

 Collection_Capacity_Coefficients

Collection capacity coefficient for product p

 hCap[h]

Capacity for hybrid center h

5.      All the text files follow the following sample format. (Products=2, Retailers=3, Hybrid Centers=3).

P
2
R
3
H
3
M(p)
[3, 3]
D'rp
[[476, 480], [478, 458], [480, 483]]
Drp
[[299, 250], [272, 250], [255, 268]]
rhLTC
[[6.64447, 7.7896, 2.9211], [3.63423, 4.78621, 3.14738], [6.08905, 7.34389, 1.70055]]
hm(p)LTC - [h][p][m]
[[[4.39954, 10.7587, 3.5525], [50.0591, 86.2556, 5.13426]], [[3.79271, 17.5223, 11.1379], [70.2111, 49.8024, 72.6498]], [[7.6992, 14.6272, 10.9736], [39.6622, 15.7879, 83.5602]]]
Delta[r][p]
[[0.760799, 0.77289], [0.702997, 0.729463], [0.718281, 0.73318]]                                                  Fh
[1.44773e+007, 1.54936e+007, 1.51822e+007]
Fm(p) - mpFC[p][m]
[[1.02101e+006, 1.20925e+006, 1.15693e+006], [1.51668e+006, 1.56021e+006, 1.43467e+006]]                                   pdPC - [p][h]
[[36.1182, 34.0571, 30.2031], [52.3546, 51.7581, 49.1857]]           pkPC - [p][h]
[[629.786, 643.444, 669.231], [1001.34, 959.652, 941.519]]
POemPC[p][m]
[[673.267, 671.105, 773.797], [1081.28, 1004.03, 1088.2]]
PRemanPC[p][m]
[[131.865, 127.704, 135.468], [202.914, 197.062, 192.55]]
MCap[p][m]
[[1.02101e+006, 1.20925e+006, 1.15693e+006], [1.51668e+006, 1.56021e+006, 1.43467e+006]]
Alpha[p][m(p)]
[[0.948111, 0.934389, 0.831339], [0.95461, 0.92789, 0.892436]]
Distribution_Capacity_Coefficients
[1, 5]
Collection_Capacity_Coefficients
[1, 2]                                                        hCap[h]
[9787.92, 9246.38, 9037.32]

 
 

------------------